• Manufacturer Aluminum Oxygen Gas Cylinder Medical Use
  • Manufacturer Aluminum Oxygen Gas Cylinder Medical Use
  • Manufacturer Aluminum Oxygen Gas Cylinder Medical Use
  • Manufacturer Aluminum Oxygen Gas Cylinder Medical Use
  • Manufacturer Aluminum Oxygen Gas Cylinder Medical Use
  • Manufacturer Aluminum Oxygen Gas Cylinder Medical Use

Manufacturer Aluminum Oxygen Gas Cylinder Medical Use

Capacity: 0.5L~50L
Working Pressure: 150bar
Low Temperature: -60c
Transport Package: Carton/Wooden Case/Pallet
Specification: GB, EN, DOT, ISO
Trademark: ASF
Samples:
US$ 70/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MED0001
Origin
China
HS Code
76130010
Production Capacity
200, 000 Pieces/Year

Product Description

Alsafe Company is the professional manufacturer of Aluminum gas cylinder.
The products for medical Oxygen are of broad range. Made to DOT standard.

Lightweight and resist corrosion. The strictest system of quality control.
Extensively adopted by customers from domestic and abroad.


. Brief introduction of the product:
Manufacturer Aluminum Oxygen Gas Cylinder Medical Use
Manufacturer Aluminum Oxygen Gas Cylinder Medical UseManufacturer Aluminum Oxygen Gas Cylinder Medical Use
. Technical data of Manufacturer Aluminum Oxygen gas cylinder medical use:
Model  Oxygen Capacity Water
Capacity
Outer Diameter Length(no valve) Weight(no valve)
        liter / lb liter        mm / in        mm / in kg / lbs
M2 40 0.13 0.3 63.5 2.5 145 5.7 0.3 0.6
M4 or A 113 0.36 0.7 81.5 3.2 221 8.7 0.7 1.5
M6 or B 165 0.52 1 81.5 3.2 300 11.8 1 2.3
ML6 165 0.52 1.2 111 4.4 198 7.8 1.3 2.9
ML7 195 0.61 1.4 111 4.4 231 9.1 1.5 3.2
M9 or C 255 0.8 1.7 111 4.4 277 10.9 1.7 3.7
D 425 1.34 2.9 111 4.4 424 16.7 2.4 5.4
M22 597 1.88 3.9 133 5.2 414 16.3 3.7 8
E 680 2.14 4.6 111 4.4 645 25.4 3.6 7.8
M60 1607 5.06 10.5 184 7.25 582 22.9 10.1 22.3
M90 2402 7.56 15.7 184 7.25 828 32.6 13.7 30.3
M122 3272 10.3 21.4 203.2 8 919 36.2 17.9 39.5
M150 4017 12.65 28.9 203.2 8 1194 47 22.1 48.8
Manufacturer Aluminum Oxygen Gas Cylinder Medical Use
. Usual types of fitted valve for choice:
Type of valve Features
CGA870 post valve with toggle The most convenient to turn on and off.
Don't require wrench.
Adopted for Oxygen cylinder: M2, M4, M6, ML6, M9, D, Jumbo D and E

 
CGA870 post valve No Toggle. Requires wrench.
Adopted for Oxygen cylinder: M2, M4, M6, ML6, M9, D, Jumbo D and E

 
Regulator Aluminum body and brass core. Outlet pressure 50psi
Flowmeter range: 0-4, 0-8, 0-10, 0-12, 0-15 or 0-25 LPM

 
Manufacturer Aluminum Oxygen Gas Cylinder Medical Use



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now